<?xml version="1.0" standalone="yes"?>  <DATAPACKET Version="2.0"><METADATA><FIELDS><FIELD attrname="PRO_CODEMP" fieldtype="i2" required="true"/><FIELD attrname="PRO_ANOLIC" fieldtype="i4" required="true"/><FIELD attrname="PRO_NUMELIC" fieldtype="i4" required="true"/><FIELD attrname="PRO_NUME" fieldtype="i4" required="true"/><FIELD attrname="PRO_CODEMI" fieldtype="i4" required="true"/><FIELD attrname="PRO_DTVAL" fieldtype="date"/><FIELD attrname="PRO_MARCA" fieldtype="string" WIDTH="40"/><FIELD attrname="PRO_BLOQ" fieldtype="string" SUBTYPE="FixedChar" WIDTH="1"/><FIELD attrname="PRO_OBS" fieldtype="string" WIDTH="50"/><FIELD attrname="PRO_QTD" fieldtype="fixedFMT" DECIMALS="4" WIDTH="15"/><FIELD attrname="PRO_QTD_VEN" fieldtype="fixedFMT" DECIMALS="4" WIDTH="15"/><FIELD attrname="PRO_SITU" fieldtype="string" SUBTYPE="FixedChar" WIDTH="1"/><FIELD attrname="PRO_VLRUNI" fieldtype="fixedFMT" DECIMALS="4" WIDTH="15"/><FIELD attrname="PRO_VLTOTAL" fieldtype="fixedFMT" DECIMALS="4" WIDTH="15"/><FIELD attrname="PRO_MOTIVBLOQ" fieldtype="string" WIDTH="150"/><FIELD attrname="PRO_CLASSIF" fieldtype="i4"/><FIELD attrname="ITE_CODPROD" fieldtype="i4"/><FIELD attrname="ITE_QTD" fieldtype="fixedFMT" DECIMALS="4" WIDTH="15"/><FIELD attrname="ITE_QTD_MI" fieldtype="fixedFMT" DECIMALS="4" WIDTH="15"/><FIELD attrname="ITE_NUME" fieldtype="i4"/><FIELD attrname="ITE_UNID" fieldtype="string" WIDTH="2"/><FIELD attrname="ITE_DESC" fieldtype="bin.hex" SUBTYPE="Text" WIDTH="1"/><FIELD attrname="LIC_ANOMODAL" fieldtype="i4"/><FIELD attrname="LIC_NUMMODAL" fieldtype="i4"/><FIELD attrname="MOD_DESC" fieldtype="string" WIDTH="40"/><FIELD attrname="LIC_DATA" fieldtype="date"/><FIELD attrname="PRO_DESC" fieldtype="string" WIDTH="55"/><FIELD attrname="EMI_DESC" fieldtype="string" WIDTH="100"/><FIELD attrname="VERSAO" fieldtype="string" WIDTH="20"/><FIELD attrname="EMP_NOME" fieldtype="string" WIDTH="100"/><FIELD attrname="EMP_CNPJ" fieldtype="string" WIDTH="20"/><FIELD attrname="EMI_CPFCNPJ" fieldtype="string" WIDTH="20"/><FIELD attrname="EMI_NAT" fieldtype="string" WIDTH="1"/><FIELD attrname="REP_CPF" fieldtype="string" WIDTH="11"/><FIELD attrname="REP_NOME" fieldtype="string" WIDTH="60"/><FIELD attrname="REP_DOCUM" fieldtype="string" WIDTH="25"/><FIELD attrname="LIC_PRZENTPRO" fieldtype="date"/><FIELD attrname="LIC_DTABERT" fieldtype="date"/><FIELD attrname="LIC_HRABERT" fieldtype="time"/><FIELD attrname="ITE_VLREF" fieldtype="fixedFMT" DECIMALS="4" WIDTH="15"/><FIELD attrname="ITE_CODLOTE" fieldtype="i4"/><FIELD attrname="LOT_DESLOT" fieldtype="string" WIDTH="60"/><FIELD attrname="LIC_AVALI" fieldtype="string" WIDTH="1"/><FIELD attrname="AUX_OBSFINAL" fieldtype="bin.hex" SUBTYPE="Text"/><FIELD attrname="ENVIA_VLREF" fieldtype="string" WIDTH="1"/><FIELD attrname="LIC_REGPRECO" fieldtype="string" WIDTH="1"/><FIELD attrname="REP_ENDE" fieldtype="string" WIDTH="100"/><FIELD attrname="REP_NUMERO" fieldtype="string" WIDTH="10"/><FIELD attrname="REP_COMPLEMENTO" fieldtype="string" WIDTH="40"/><FIELD attrname="REP_CEP" fieldtype="string" WIDTH="9"/><FIELD attrname="REP_UF" fieldtype="string" WIDTH="2"/><FIELD attrname="REP_NOMECIDADE" fieldtype="string" WIDTH="50"/><FIELD attrname="PRO_REGANVISA" fieldtype="string" WIDTH="13"/><FIELD attrname="PRO_PRODCATMATCOD" fieldtype="string" WIDTH="9"/><FIELD attrname="PRO_CNPJFABRI" fieldtype="string" WIDTH="14"/></FIELDS><PARAMS CHANGE_LOG="1 0 4"/></METADATA><ROWDATA><ROW RowState="4" PRO_CODEMP="1" PRO_ANOLIC="2020" PRO_NUMELIC="33" PRO_NUME="1" PRO_CODEMI="0" PRO_QTD="1.0000" ITE_CODPROD="24559" ITE_QTD="1.0000" ITE_NUME="1" ITE_UNID="UN" ITE_DESC="AQUISIÇÃO DE 01 (UM) EQUIPAMENTO DE ULTRASSON DOPPLER PARA USO GERAL COM SISTEMA DIGITAL DE ALTA RESOLUÇÃO PARA EXAMES ABDOMINAIS, GINECOLÓGICOS, OBSTÉTRICOS, 4 d, DE MAMA, PEQUENAS PARTES, MUSCULO ESQUELETICO, VASCULARES, CARDIOLOGIA ADULTO E PEDIÁTRICA COM AS SEGUINTES CARACTERÍSTICAS TÉCNICAS MÍNIMAS:&#013;&#010;SISTEMA TRANSPORTÁVEL, MONTADO SOBRE RODÍZIOS COM SISTEMAS DE FREIOS; CONFIGURAÇÕES DE IMAGENS NOS MODOS B,M, DOPPLER COLOR, DOPPLER PULSADO , DOPPLER CONTÍNUO, DOPPLER TECIDUAL, POWER DOPPLER (ANGIO), POWER DOPPLER DIRECIONAL E HPRF. OS MODOS BÁSICOS DE IMAGEM B, M D DOPPLER PULSADO DEVEM PERMITIR COLORIZAÇÃO; NO MINÍMO 04 (QUATRO) PORTAS ATIVAS PARA CONEXÃO DE 04 TRANSDUTORES SIMULTÂNEOS, SELECIONÁVEIS PELO PAINEL, LIGADOS DIRETAMENTE AO APARELHO SEM ADPTADORES, SEM CONSIDERAR O CONECTOR TIPO CANETA PARA DOPPLER CEGO (PEDOFF); MONITOR LCD EM LED 17&quot; / DE ALTA RESOLUÇÃO COM BRAÇO ARTICULÁVEL COM AJUSTE DE INCLINAÇÃO E POSSIBILIDADE DE ANGULAÇÃO VERTICAL E HORIZONTAL;&#013;&#010;SOFTWARE DE HARMÔNICA DE TECIDO DE PLSO INVERTIDO COMPATÍVEL COM TODOS OS TRANSDUTORES PARA PROPORCIONAR MELHOR RESOLUÇÃO DA IMAGEM; DISPONIBILISAR FERRAMENTA EDUCACIONAL COM O OBJETIVO DE AUXILIAR NA REALIZAÇÃO DE EXAMES; SOFTWARE DE IMAGEM DO TIPO ESTENDIDA OU PANORÂMICA; SOFTWARE DE COMPOSIÇÃO ESPACIAL DE IMAGENS E FEIXES ENTRELAÇADOS; &#013;&#010;FUNÇÃO DE OTIMIZAÇÃOAUTOMÁTICA DE GANHO PARA O MODO BIDIMENSIONAL POR MEIO DE UM BOTÃO; AJUSTE AUTOMÁTICO DO ESPECTRO DOPPLER; IMAGEM TRAPEZOIDAL PARA TRANSDUTORES LINEARES; INCLINAÇÃO INDEPENDENTE DA IMAGEM MODO B, DOPPLER PULSADO E DOPPLER COLORIDO PARA O TRANSDUTOR LINEAR; TAXA DE ATUALIZAÇÃO PARA O MODO B; PROFUNDIDADE MÁXIMA DE PELO MENOS 35 CM; CAPACIDADE ILIMITADA PARA PROGRAMAÇÕES DE AJUSTE DE IMAGENS QUE PERMITAM A OTIMIZAÇÃO DO APARELHO PARA CADA TIPO DE EXAME;&#013;&#010;MODOS DE IMAGEM B SIMPLES, 4B, DUAL B + B/C), M/B, M, B/D, D, B + COR + DOPPLER EM TEMPO REAL (MODO TRIPLEX);&#013;&#010;CAPACIDADE DE MAGNIFICAÇÃO DA IMAGEM, TANTO EM TEMPO REAL QUANTO COM A IMAGEM CONGELADA;&#013;&#010;FUNÇÃO &quot;CINE LOOP&quot; COM CAPACIDADE PARA ARMAZENAMENTO DE, PELO MENOS 3000 QUADROS OU 180 SEGUNDOS;&#013;&#010;PAINEL DE COMANDO ERGONÔMICO, QUE PERMITA AJUSTES DE ALTURA E ROTAÇÃO, QUE POSSUA TECLADO ALFANUMÉRICO FÍSICO, NO MÍNIMO 08 BOTÕES FÍSICOS PARA AJUSTE DE TGC E SISTEMA DE MANUSEIO DO CURSOR POR TRACKBALL OU SIMILAR;&#013;&#010;TELA DIGITAL &quot;TOUCH SCREEN&quot; INTEGRADA AO PAINEL DE COMANDO, COM NO MÍNIMO 10 POLEGADAS, PROGRAMÁVEL E ADAPTÁVEL; DEVE PROPORCIONAR OS SEGUINTES COMANDOS:&#013;&#010;POSSIBILIDADE DE PROGRAMAÇÃO DE NOVAS MEDIDAS, FÓRMULAS E TABELAS; DOPPLER (VELOCIDADE, TEMPO, ACELERAÇÃO, FREQUÊNCIA CARDÍACA, RELAÇÃO SÍSTOLE/DIÁSTOLE, ÍNDICE DE RESISTÊNCIA, ÍNDICE DE PULSATILIDADE COM TRAÇADO AUTOMÁTICO, VOLUME DE FLUXO);&#013;&#010;PACOTES DE MEDIDAS PARA CARDIOLOGIA, VASCULAR E OBSTETRÍCIA; MODO B (DISTÂNCIA, VOLUME, ÁREA, CIRCUNFERÊNCIA, ÂNGULO, ESTENOSE, FUNÇÃO DO VE); MODO M (TEMPO, DISTÂNCIA, ACELERAÇÃO, FREQUÊNCIA CARDIÁCA, FUNÇÃO DO VE);&#013;&#010;RESISTÊNCIA, ÍNDICE DE PULSATILIDADE COM TRAÇADO AUTOMÁTICO, VOLUME DE FLUXO);&#013;&#010;CÁLCULO AUTOMÁTICO DA ESPESSURA MÉDIA DA ÍNTIMA DA ARTÉRIA CARÓTIDA;&#013;&#010;O EQUIPAMENTO DEVE DISPOR DE SISTEMA DE ARMAZENAMENTO DE IMAGEM EM CD OU DVD E PEN DRIVE (PORTA USB); SISTEMA DE IMPRESSÃO DE IMAGENS (LAUDO) COM POSSIBILIDADE DE AJUSTE DE ATÉ 6 IMAGENS POR PÁGINA; HD COM CAPACIDADE NÃO INFERIOR A 500MB; POSSIBILIDADE DE COMUNICAÇÃO EM PADRÃO DICOM 3.0 COM OS SEGUINTES PROTOCOLOS: STORAGE, PRINT, MWM (MODALITY WORKLIST MANAGEMENT); SAÍDAS DE VÍDEO VGA, S-VÍDEO E DVI, ETHERNET E SAÍDA DE ÁUDIO E COM NO MÍNIMO 6 PORTAS USB, SEM USO DE ADAPTADORES; POSSIBILIDADE DE TRANSFERÊNCIA DE IMAGEM E RELATÓRIOS DIRETAMENTE PARA UM PC ATRAVÉS DE REDE DE DADOS FÍSICA OU WIRELESS; SISTEMA DE ARMAZENAMENTO DE IMAGENS ESTÁTICAS (FOTOS) E IMAGENS DINÂMICAS (CLIPS) COM RECURSO PARA EXPORTAR EM FORMATO (BMP, JPG, AVI OU SIMILARES) E DICOM; SISTEMA QUE PERMITA TRANSFERÊNCIA DIRETA DE IMAGENS PARA UM DISPOSITIVO MÓVEL ATRAVÉS DE APLICATIVO; &#013;&#010;CONTER: NOBREAK BIVOLT AUTOMÁTICO (127~240 V) COMPATÍVEL COM O EQUIPAMENTO; INSTALAÇÃO E TREINAMENTO; COMPATIBILIDADE DA IMPRESSORA E COLORIDA, MANUAIS DO EQUIPAMENTO EM PORTUGUÊS; ENTREGA EM ATÉ 30 DIAS; TRANSDUTORES MÍNIMOS, TODOS MULTIFREQUENCIAIS BANDA LARGA: TRANSDUTOR ENDOCAVITÁRIO QUE ATRNDA NO MÍNIMO A FAIXA DE FREGUÊNCIA DE 3,0 A 12,0 MHz COM ABERTURA DE PELO MENOS 136 GRAUS E 128 ELEMENTOS CRISTAIS; TRANSDUTOR CONVEXO QUE ATENDA NO MÍNIMO A FAIXA DE FREQUÊNCIA DE 2,0 A 6,0 MHz COM ABERTURA DE PELO MENOS 70 GRAUS E 128 ELEMENTOS (CRISTAIS); TRANSDUTOR LINEAR QUE ATENDA NO MÍNIMO A FAIXA DE FREGUÊNCIA DE 4,0 A 13,0 MHz COM NO MÍNIMO 128 ELEMENTOS (CRISTAIS); TER DISPONÍVEL PARA CONFIGURAÇÃO FUTURA SOFTWARE PARA CÁLCULO AUTOMÁTICO DA TRANSLUCENCIA NUCAL E DE MEDIDAS OBSTÉTRICAS (BPD/HC/FL/AC/OFD); SOFTWARE PARA ANÁLISE QUANTITATIVA DA ELASTICIDADE DE TECIDOS; SOFTWARE COMPLETO DE MODO TD, AVALIAÇÃO QUANTITATIVA DO MOVIMENTO E SINCRONIZAÇÃO DO MIOCÁRDIO; SOFTWARE PARA IMAGEM TRIDIMENCIONAL; SOFTWARE PARA A CAPTURA DE IMAGENS FETAIS REALÍSTICAS; MODULO DE ECG INTEGRADO PARA SINCRONIZAÇÃO DOS SINAIS VITAIS COM AS IMAGENS CARDÍACAS E VASCULARES; DOPPLER CONTÍNUO, MODO M ANATÔMICO E MODO M ANATÔMICO COLORIDO; SOFTWARE DE VISULAIZAÇÃO DE CONTRASTE EM TEMPO REAL.&#013;&#010;&#013;&#010;" LIC_ANOMODAL="2020" LIC_NUMMODAL="22" MOD_DESC="Pregão Presencial" PRO_DESC="APARELHO DE ULTRASSOM COLORIDO (DOPPLER) PARA USO GERAL" EMI_DESC="" VERSAO="30" EMP_NOME="PREFEITURA MUNICIPAL DE COXILHA" EMP_CNPJ="92411933000190" EMI_CPFCNPJ="" EMI_NAT="" LIC_PRZENTPRO="20200526" LIC_DTABERT="20200526" LIC_HRABERT="09:00:00000" ITE_CODLOTE="0" LOT_DESLOT="" LIC_AVALI="1" ENVIA_VLREF="N" LIC_REGPRECO="N" PRO_REGANVISA="" PRO_PRODCATMATCOD="" PRO_CNPJFABRI=""/></ROWDATA></DATAPACKET>